Sunday, December 2, 2012

Screen Doors and Submarines

What's wrong in this picture?Utilitarian, a fancy and I might add a little hard to pronounce word that means useful, practical, handy. The opposite of which is useless, worthless and unhandy. Is unhandy a word? Any how, in my eventful explorations of houses, I find all manner of attempts at reinventing the wheel. Some people put forth great effort merely to accomplish failure. Leaving behind monuments to their creativity and misguided endeavor.

So it was recently while traversing a roof top. A high roof with a low pitch. If I'm going to be that high, I'd rather be on a gentle slope. Not to pick on any of my fellow inspectors, but this was an instance where being up close and personal was very revealing and somewhat amusing.

Before I step onto any roof I scan the field, just to see if anything jumps out at me. I look at the shingles close to me, the gutter, the penetrations and step on to the roof. On this low pitched roof things were leaping out at me.

Fire caulk used to "seal" worn flashing boot.

One of the most frequent issues I find with low sloped roofs is penetrations that have been incorrectly flashed. Almost every time the plumbing vents have a typical sloped roof flashing collar installed on the pipe that has been slathered with tar and or caulk to "seal" it.

Through this particular roof were several pipes which drew me like a tractor beam. The first one I examined had some wonderful variations on the caulking theme, one that was new to me. I love finding new tricks to tell my clients NOT to do.

The rubber collar was very loosey goosey, not even closely sealing off the pipe from rain and the elements. Since this sloped roof vent had been installed under the rolled asphalt covering, it could not be easily replaced with another wrong one. This problem screamed for a solution outside the box.

Pipe inside a pipe or up periscope Way out.?

The person who found this solution is a creative thinker. Instead of the usual and ugly black roof tar or sticky old caulk, expandable fire caulk was sprayed in from below. No leaks and its fire safe!

Then there was the pipe in the pipe. Um, how exactly is that water proof? Oh right, more fire caulk. You have to love expandable foam.

I have saved the best for last.

The vent opening faces UP the roof slopeThe roof vent installed near the lower part of the slope. Wait that's not the best part. Can you see the problem here? I would bet most people can, with the exception of the person who installed the vent.

It's backwards! The screened opening faces up the slope in the direction the water flows.

I think this problem needs another solution from a spray can.

?

James Quarello
Connecticut Home Inspector
Former SNEC-ASHI President
NRSB #8SS0022
JRV Home Inspection Services, LLC

 ASHI Certified Inspector

To find out more about our other high tech services we offer in Connecticut click on the links below:

Serving the Connecticut Counties of Fairfield, Hartford, Middlesex, New Haven, Southern Litchfield and Western New London.

?

Source: http://activerain.com/blogsview/3539144/screen-doors-and-submarines

joseph kony ipad 3 release date apple store down apple live blog ohio primary cell phone jammer g8 summit

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.